Tyler was very friendly and professional overseeing the install of a new breaker panel (I had an old Murray panel which was failing) and a new circuit I needed in the house. Tyler was a great communicator and even completed the job quicker than expected. I would highly recommend this company for services.
Offered a good price as well!
Response from EaZy Electrical & Plumbing :
We are happy you had a great experience with our local plumber, hopefully you have no more problems but if so, no worries we have great warranties on all of our plumbing and electrical work!
Would highly recommend Tyler Day to take care of all your electrical needs.
Toby is the best servce person ever. He truly went out of his way in providing additional information.
Addressed a severe toilet blockage. Isolated the water supply and removed the toilet to access the drain line. Utilized a closet auger to clear a significant obstruction within the drain. Inspected the flange for damage and re-seated the toilet with a new wax ring, ensuring a proper seal. Tested flushing action to confirm complete restoration of flow.
Investigated a persistent leak at the base of a toilet. Disconnected the water supply and carefully removed the toilet. Discovered a failed wax ring and corroded closet bolts. Cleaned the flange surface and replaced the bolts and wax ring with new components. Re-installed the toilet, ensuring a level and secure fit. Restored water supply and verified a leak-free seal.
Electrician is here installing a new 200 amp main breaker panel
Potable water pressure at main: 55 PSI (acceptable). Minor corrosion noted on kitchen cold water isolation valve; monitor. Internal camera inspection of bathroom lavatory drain revealed moderate organic/soap buildup in P-trap. Estimate includes optional valve replacement (compliant ball valve) and hydro-jetting for drain cleaning to optimize flow. No obligation.
Installed dedicated 20A, 120V circuit for new microwave per NEC 210.11(C)(2). Ran 12/2 AWG NM-B cable from existing panel to specified location, securing with appropriate staples. Installed new single receptacle in a dedicated box, ensuring proper grounding to the equipment grounding conductor. Verified voltage and polarity at the outlet. Circuit breaker labeled accordingly. Free estimate for future electrical needs.
Finalized device installations per work order. Replaced five standard duplex receptacles with tamper-resistant (TR) receptacles as per NEC 406.12. Installed three new AFCI/GFCI combination circuit breakers in panel to provide enhanced protection on branch circuits serving bedrooms and bathrooms (NEC 210.12 & 210.8). Verified proper grounding and tested all devices for correct operation and voltage. Updated panel schedule. Free estimate available for any future electrical upgrades or repairs.
Electrician restoring power to bathroom lighting.
Need a dependable residential electrical repair and installation service? Our experienced technicians handle everything from outlet replacements to whole house rewiring. Trust us to keep your home safe and functional. Contact us today for a free estimate.
If you are waiting for a technician to arrive between 11:00 AM and 3:00 PM and they have not shown up yet, please contact us for an updated ETA. We apologize for any inconvenience and are committed to providing you with excellent service for [specific service].
Electrician relocating Panel from staircase to laundry room.
Electrician replacing ceiling fan in living room.
Electrician replacing ceiling fan.